Photo cell with adjustable measuring range, 24 V, 1 channel, 3-60 000 lux, IP54
Photo cell for outdoor applications (IP54). To be used in combination with the analogue sensor module (550-00230). The photo cell has a variable light sensitivity between 3 and 300 lux, 30 lux and 3 kilolux, 300 lux and 30 kilolux or 600 lux and 60 kilolux.
Product details
Light sensor, 24 V, 3 lux – 60000 lux, IP54, grey
This photo cell is used in combination with a daylight control module (360-35010). The light sensitivity can be set from 3 to 300 lx, from 30 lx to 3 klx, from 300 lx to 30 klx or from 600 lx to 60 klx. This photo cell is suitable for outdoor applications and has an IP54 protection degree.
Finishing colour: grey
Specification description
Light sensor, 24 V, 3 lux – 60000 lux, IP54, grey.
- Detector technology: lux
- Input voltage: 24 Vdc ± 10 %
- Detector output: 0-10 V
- Number of channels: 1 channel
- Light intensity range: 3 lux – 60000 lux
- Ambient temperature: -40 – +50 °C
- Mounting method: surface mounting
- Usage: for outdoor use
- Dimensions (HxWxD): 52 x 52 x 34.5 mm
- Protection degree: IP54
- Marking: CE
Related products
Connected controller for Niko Home Control II
The connected controller is the central module of every Niko Home Control installation for bus wiring. This module contains firmware that can only be programmed with the Niko Home Control programming software 2.1.1 or higher. It covers all basic functions on which a Niko Home Control installation is built. The basic functions include: • The intelligence directing the logic to the installation. Through the configuration software, the logic is saved locally on the controller. • The power supply module providing an input voltage of 26 V to the bus, the cabinet modules and the controls. Depending on the size of the installation, separate power supply modules can be added. • The connection to Niko Home Control IP devices such as touchscreens and external video units. A built-in router allows the user to connect up to 3 devices directly to the controller. With an extra switch, this number can be increased. • The connection to the internet. This enables the user to control the installation both indoors and outdoors (via mobile networks such as 3G, 4G, GPRS or Wi-Fi hotspot) using mobile devices (smartphones and tablets with iOS or Android). The module has a TEST button to verify the proper functioning and status of all other modules. Each installation must consist of one connected controller. After registration, your installation is connected, enabling control through the app via your smartphone and tablet, and you can enjoy the Niko services for upgrade or diagnosis of the installation.
Power supply
The power supply, in combination with the connected controller, provides an extra input voltage of 26 V to the bus, modules and controls. An extra power supply is only necessary in installations for which the power of the built-in power supply of the connected controller is insufficient. Up to 2 extra power supplies can be connected to installations with a connected controller. The MASTER button is not used, as the built-in power supply of the connected controller is always the master. For more information on the required number of power supplies, you can consult the installation manual.
Rail coupler
This module is always mounted first on the left at the start of a new row of DIN rail modules that doesn't contain a connected controller or power supply. Interconnect the power supply and bus through the contacts at the top and bottom.