! This version of Internet Explorer is not supported anymore !

We recommend to visit our website with another browser (Microsoft Edge, Chrome, Firefox, ...)

Presence detector, 230 V, master, 2 channels, 24 m, IP54, for surface mounting, white

Reference code
350-20082
Technical datasheets
Technical manuals
Certificaten CE-Marking

Description

Master presence detector with increased detection range, 2x external switch input, full and semi-automatic mode, two potential-free switch outputs to switch 2 conventional lighting strips or 1x lighting plus 1x HVAC. The lux level (lux) can be freely chosen for each channel (lighting or HVAC). Range extension with up to 10 secondary detectors.

Finishing colour: white

Compatible secondary detectors: 350-20071, 350-20079, 350-20081

Specification description

Presence detector, 230 V, master, 2 channels, 24 m, IP54, for surface mounting, white.

  • Factory setting
    • sensitivity of the motion sensor: high
    • application: presence detector, daylight-dependent, automatic on/off via PIR
    • push-button application: the lighting can be switched off manually with a short push on a NO push button without having to wait for the switch-off delay (mode: 'eco off'). The lighting can also be switched on manually with a short push on the push button. The lighting is only switched on. The lighting is only switched on if the amount of daylight available in the room is insufficient. Pressing and holding the push button switches the lighting on or off for two hours irrespective of the detected movement and the registered light level.
    • switch-off delay both channels: 10 min
    • light sensitivity both channels: 200 lux

The detector has four potentiometers and six DIP switches for manually adjusting the settings:

– potentiometer 1: setting the light sensitivity for channel 1 (20 lux up to light-independent)

– potentiometer 2: setting the switch-off delay for channel 1 (2 up to 60 minutes)

– potentiometer 3: setting the light sensitivity for channel 2 (20 lux to light-independent)

– Potentiometer 4: setting the switch-off delay for channel 2 (2 to 60 minutes)

For correct setting, the detector must have an LED indicator for setting of time and lux level The four DIP switches enable the selection of various functionalities: presence or absence detection, ‘eco off’ function, daylight-dependent or daylight-independent push button. Using the two DIP switches the sensitivity of the sensor can be increased or decreased (four levels of sensitivity). Setting via the remote control: the user can use the remote control to set up the detector entirely according to his requirements (absence, presence, lux levels, push button possibilities, switch-off delay, four levels of sensitivity ..)

  • Detector technology: PIR
  • Input voltage: 230 Vac ± 10 %, 50 Hz
  • Detector output: 230 V (ON/OFF)
  • Maximum MCB rating: 10 A (limited by national installation rules)
  • Number of channels: 2 channels
  • Light intensity range: 20 lux – 1000 lux
  • Switch-off delay: 2 min – 1 h, ∞
  • Detection angle: 360°
  • Detection range (PIR): ø 24 m from a height of 3 m
  • Ambient temperature: -5 – +50 °C
  • Mounting method: surface mounting
  • Mounting height: 2 – 3.4 m
  • Usage: for indoor use only
  • Relay contact: 2 x N.O. (max. 10 A), potential-free
  • Maximum load incandescent and halogen lamps (cosφ = 1): 2300 W
  • Maximum load low voltage halogen lamps: 1200 W
  • Maximum load economy lamps (CFLi): 350 W
  • Maximum load LED lamps 230 V: 350 W
  • Maximum capacitive load: 140 µF
  • Maximum switching current: 165 A/20 ms – 800 A/200 µs
  • Dimensions (HxWxD): 117.3 x 117.3 x 64.1 mm
  • Protection degree: IP54
  • Impact resistance: IK04
  • Protection class: Class I device
  • Marking: CE
  • Certification marks: SundaHus, Byggvarubedömningen
The article above is part of this product:

Related products:

Favorites ( 0 )